14 2 14 gauge 2 conductors etc.
Underground service entrance cable requirements.
Current transformer cabinets overhead or underground service window type ct s figure 11.
600 v maximum voltage rating for typical residential nm electrical cable.
Service entrance disconnect and location shall conform to the latest version of the nec and all local ordinances.
How to translate the electrical wire markings on nmc cable.
14 2 wg 14 gauge 2 conductors with ground etc.
Cu copper.
For overhead service weather head must be a minimum of three feet above the roof.
At 18 inches you can use thwn 2 conductors inside a continuous length of pvc conduit which protects the wire all the way through the trench to the house.
A disconnecting means must be provided for all.
Type se or service entrance cable having a flame retardant moisture resistant covering or type use which is service entrance cable identified for underground use having a moisture resistant covering but not required to have a flame retardant covering.
5trenches to be in as straight and direct a line as possible.
According to 338 2 there are two types of service entrance cables.
Any conduit crossing under a road shall be schedule 80.
Minimum 6 copper ground wire securely stapled to wall.
Single mobile home underground service pressure treated post figure 9a.
Nec 300 5 underground wiring conduits and raceways direct buried cable or conduit or other raceways shall meet the following minimum cover requirements.
4conduit minimum depth 36 inches.
Conduits installed less than 36 inches in depth require cooperative engineering approval and shall beencased in concrete to cooperative specs depths specified are to finished grade.
Direct burial cable rigid or intermediate metal conduit non metallic raceway pvc 24 inches 6 inches 18.
For underground service the poured footing must be notched out for the conduit.
For service entrances of 201 to 400 amperes as determined by the nameplate ampacity of the service disconnect a rain tight current transformer enclosure constructed of code gauge metal with an approved mounting base for bar type current transformers shall be used.
Requirements for nonmetallic conduits nonmetallic conduits or raceways approved for buried cable give less protection than metal conduits and require greater burial depths.
Single mobile home underground service alternate meter pedestal figure 10.
Single phase underground service meter installation figure 9.
12 2 12 gauge 2 conductors.
Meter base mounted on exterior wall of house or mobile manufactured home.